Define current sensitivity and voltage sensitivity of a galvanometer. Increasing the current sensitivity may not necessarily increase the voltage sensitivity of a galvanometer. Justify.
Answer
639.6k+ views
Hint: Galvanometer is used to detect current in a circuit. Current sensitivity determines how much a galvanometer will deflect on passing some current through it. Similarly, voltage sensitivity determines how much the galvanometer will undergo deflection when some potential difference is applied across its ends.
Formula used: \[{{I}_{s}}=\dfrac{\theta }{I}=\dfrac{nBA}{c}\]
\[{{V}_{s}}=\dfrac{nBA}{cR}\]
Complete step by step answer:
Current sensitivity is defined as the deflection caused in the galvanometer per unit flow of current. It is given by-
\[{{I}_{s}}=\dfrac{\theta }{I}=\dfrac{nBA}{c}\] ----- (1)
Here, \[\theta \] is the angle by which galvanometer needle gets deflected
\[I\] is the current flowing through the galvanometer
\[n\] is the number of turns in the coil of the galvanometer
\[B\] is a magnetic field around the coil.
\[A\] is area of cross section of the coil
\[c\] is the restoring torque per unit twist
Voltage sensitivity is defined as deflection caused in the galvanometer when a unit potential difference is applied across it.
It is given by-
\[{{V}_{s}}=\dfrac{\theta }{V}=\dfrac{\theta }{IR}\] ---- (2)
Here, \[V\] is the potential drop
\[R\] is the resistance
From eq (1) and eq (2), we get,
\[{{V}_{s}}=\dfrac{nBA}{cR}\]
So, the current sensitivity is \[{{I}_{s}}=\dfrac{\theta }{I}=\dfrac{nBA}{c}\] and the voltage sensitivity is \[{{V}_{s}}=\dfrac{nBA}{cR}\]
As we can see, voltage sensitivity depends on current sensitivity as well as resistance. So, if we increase current sensitivity, resistance may or may not vary. For example- if we increase current sensitivity by increasing the number of turns in the coil, the resistance will also increase. Hence, the voltage sensitivity may not be affected in this case. If the current sensitivity and resistance increase or decrease in the same ratio there will be no change in voltage sensitivity.
Therefore, the current sensitivity may not necessarily increase the voltage sensitivity of a galvanometer.
Note: Galvanometer is a device that is used to detect current in a circuit. It can be modified to act like an ammeter or voltmeter. When current flows through the coil of the galvanometer, a force acts on it due to which the coil is twisted and causes the needle of the galvanometer to deflect.
Formula used: \[{{I}_{s}}=\dfrac{\theta }{I}=\dfrac{nBA}{c}\]
\[{{V}_{s}}=\dfrac{nBA}{cR}\]
Complete step by step answer:
Current sensitivity is defined as the deflection caused in the galvanometer per unit flow of current. It is given by-
\[{{I}_{s}}=\dfrac{\theta }{I}=\dfrac{nBA}{c}\] ----- (1)
Here, \[\theta \] is the angle by which galvanometer needle gets deflected
\[I\] is the current flowing through the galvanometer
\[n\] is the number of turns in the coil of the galvanometer
\[B\] is a magnetic field around the coil.
\[A\] is area of cross section of the coil
\[c\] is the restoring torque per unit twist
Voltage sensitivity is defined as deflection caused in the galvanometer when a unit potential difference is applied across it.
It is given by-
\[{{V}_{s}}=\dfrac{\theta }{V}=\dfrac{\theta }{IR}\] ---- (2)
Here, \[V\] is the potential drop
\[R\] is the resistance
From eq (1) and eq (2), we get,
\[{{V}_{s}}=\dfrac{nBA}{cR}\]
So, the current sensitivity is \[{{I}_{s}}=\dfrac{\theta }{I}=\dfrac{nBA}{c}\] and the voltage sensitivity is \[{{V}_{s}}=\dfrac{nBA}{cR}\]
As we can see, voltage sensitivity depends on current sensitivity as well as resistance. So, if we increase current sensitivity, resistance may or may not vary. For example- if we increase current sensitivity by increasing the number of turns in the coil, the resistance will also increase. Hence, the voltage sensitivity may not be affected in this case. If the current sensitivity and resistance increase or decrease in the same ratio there will be no change in voltage sensitivity.
Therefore, the current sensitivity may not necessarily increase the voltage sensitivity of a galvanometer.
Note: Galvanometer is a device that is used to detect current in a circuit. It can be modified to act like an ammeter or voltmeter. When current flows through the coil of the galvanometer, a force acts on it due to which the coil is twisted and causes the needle of the galvanometer to deflect.
Recently Updated Pages
What is BLO What is the full form of BLO class 8 social science CBSE

Explain the Treaty of Vienna of 1815 class 10 social science CBSE

10 examples of friction in our daily life

Draw a diagram of nephron and explain its structur class 11 biology CBSE

Write structures of the following compounds i 2 Chloro3methylpentane class 11 chemistry CBSE

A Paragraph on Pollution in about 100-150 Words

Trending doubts
Draw a labelled sketch of the human eye class 12 physics CBSE

Which are the Top 10 Largest Countries of the World?

Differentiate between homogeneous and heterogeneous class 12 chemistry CBSE

Draw ray diagrams each showing i myopic eye and ii class 12 physics CBSE

Which is the correct genotypic ratio of mendel dihybrid class 12 biology CBSE

What is the Full Form of PVC, PET, HDPE, LDPE, PP and PS ?